Operating temperature range
|
-40℃ to +85℃
|
|
Rating (max.)/(min.) (Resistive load)
|
0.3A 4V DC/50µA 3V DC
|
|
Electrical performance
|
Contact resistance (Initial performance/After lifetime)
|
70mΩ max./130mΩ max.
|
|
Insulation resistance
|
100MΩ min. 500V DC
|
|
Voltage proof
|
500V AC for 1 minute
|
|
Mechanical performance
|
Terminal strength
|
3N for 1 minute
|
|
Actuator strength
|
Operating direction
|
10N
|
|
Pulling direction
|
10N, Static force
|
|
Resistance to soldering heat
|
Manual soldering
|
300±5℃,3s max.
|
|
Reflow soldering
|
Refer to soldering conditions
|
|
Durability
|
Operating life without load
|
10,000 cycles 100mΩ max.
|
Operating life with load (Load: as ratings)
|
10,000 cycles 130mΩ max.
|
|
Environmental performance
|
Cold
|
-20±2℃ for 96h
|
|
Dry heat
|
85±2℃ for 96h
|
|
Damp heat
|
40±2℃, 90 to 95%RH for 96h
|
|
Example of Reflow Soldering Condition (Reference)
|
|
|
Double heating method with infrared heater.
|
|
|
2. Temperature measurement
|
|
Thermocouple 0.1 to 0.2 Φ CA (K) or CC (T) at soldering portion (copper foil surface). A heat resisting tape should be used for fixed measurement.
|
|
|
|
|
(1) The condition mentioned above is the temperature on the mounting surface of a PC board. There are cases where the PC board's temperature greatly differs from that of the switch, depending on the PC board's material, size, thickness, etc. The above-stated conditions shall also apply to switch surface temperatures.
|
|
|
(2) Soldering conditions differ depending on reflow soldering machines. Prior verification of soldering condition is highly recommended.
|
|
|
(3) Ask us for the specifications of lead-free products.
|
|
|
|
|
A(℃) 3s max. | B(℃) | C(℃) | D(s) | E(s) | F(s) | | 250 | 200 | 150 | 120 | - | - |
|
|