Travel 1.4mm
Actuator directions Horizontal
Poles 1
Positions 2
Operating force 1.5±1N
Changeover timing Not specified
Soldering Reflow
Location lug With
Operating temperature range -10℃ to +60℃
Rating (max.)/(min.) (Resistive load) 10mA 5V DC/50µA 3V DC
Electrical performance Contact resistance
(Initial performance/After lifetime)
300mΩ max./500mΩ max.
Insulation resistance 100MΩ min. 100V DC
Voltage proof 100V AC for 1 minute
Mechanical performance Terminal strength 3N for 1 minute
Actuator strength Operating direction 10N
Pulling direction 10N
Durability Operating life without load 10,000 cycles 500mΩ max.
Operating life with load
(at max. rated load)
10,000 cycles 500mΩ max.
Environmental performance Cold -40℃ 96h
Dry heat 85℃ 96h
Damp heat 40℃, 90 to 95%RH 96h
Minimum order unit (pcs.) Japan 5,000
Export 20,000
 

Dimensions

Slide Switch

Land Dimensions

Slide Switch

Circuit Diagram

Slide Switch

Packing Specifications

Taping

Number of packages (pcs.) 1 reel 5,000
1 case / Japan 10,000
1 case / export packing 20,000
Tape width (mm) 16
Export package measurements (mm) 417×409×139

Soldering Conditions

Example of Reflow Soldering Condition
1. Heating method
Double heating method with infrared heater.
2. Temperature measurement
Thermocouple 0.1 to 0.2 Φ CA (K) or CC (T) at soldering portion (copper foil surface). A heat resisting tape should be used for fixed measurement.
3. Temperature profile
A(℃)
3s max.
B(℃)C(s)D(℃)E(℃)F(s)
26023040180150120

(1) The condition mentioned above is the temperature on the mounting surface of a PC board. There are cases where the PC board's temperature greatly differs from that of the switch, depending on the PC board's material, size, thickness, etc. The above-stated conditions shall also apply to switch surface temperatures.
(2) Soldering conditions differ depending on reflow soldering machines. Prior verification of soldering condition is highly recommended.

Reference for Hand Soldering
Soldering temperature350±5℃
Soldering time3s max.


Notes are common to this series/models.

  1. This site catalog shows only outline specifications. When using the products, please obtain formal specifications for supply.
  2. Please place purchase orders per minimum order unit (integer).